EasyHeat ADKS Roof and Gutter De-Icing Heat Trace Cable

Link To EGS Home Page - New Window ehlogo.gif (3151 bytes)
We are an authorized stocking distributor for Easy Heat, Inc.


Links to other roof heating cable:
EasyHeat PSR Pre-Terminated Self-Regulating Freeze Protection Cable for Water Pipes and Roofs

Wrap-On Roof and Gutter Heating Cables.
Chromalox Commercial Grade Roof and Gutter Heat Trace Cable


Even in below freezing weather, snow on the roof will often thaw because of heat from the sun and heat loss from the house through the roof. As this melted snow reaches the roof overhang it refreezes.  Here there is no heat loss so the roof surface is much colder. As this melted snow refreezes again and again on the roof overhang, an ice dam is formed. Soon water backs up under shingles, and leaks into the house.

EASYHEAT® ADKS roof de-icing cable prevents water and ice damage by providing a clear path for melting water. It keeps roof edges, gutters and downspouts ice-free.  Versatile design adapts to most roof and gutter configurations.

It's not those big icicles that do the real damage, it's the ice you don't see that backs up in gutters and under shingles. When the ice melts it can really do a number on repair costs. Easy Heat ADKS roof de-icing cable prevents this water and ice damage by providing a clear path for melting water to flow off the roof. The versatile design adapts to most roof and gutter configurations.

  • Easy to install
  • Approved for metal and plastic gutters
  • Complete with clips and spacers


ADKS-500 Cable (100 feet, 500 watts)

ADKS Roof Application This product is intended for the sole use of preventing ice dams from forming on inclined roofs with tab shingles, in gutters and downspouts.  (Not for use on metal roofs because of the risk of overheating, use self-regulating cable instead such as PSR).  This roof de-icing cable is not intended for use as a snow melting system to clear roof of ice and snow.  This system can be installed with confidence that it will operate for years without requiring service. All components are made of the highest quality material and are tested during critical points in the manufacturing process.
ADKS Packaging w/product Each ADKS kit includes the Electric Roof De-icing Cable (Residential Grade, 120 Volt, 5 Watts/foot) and 6 foot power cord with plug and enough roof clips and cable spacers to complete the installation.

  U.S.A. UL and Canadian cUL Listed CSA Certified
CSA Certified and UL Listed to Canadian safety standards.


Figure 1

The cable should be installed over the unheated portion of the roof (E in Fig. 1) - normally the roof area above the overhang.

To design how much cable is needed, multiply the length of the roof edge that you want cable on by the following spacing factor:

If your roof overhang is: Overhang Multiplier: If your roof overhang is: Overhang Multiplier:
12" 4.0 48" 8.1
24" 5.3 60" 9.6
36" 6.8 72" 11.2

The overhang multiplier is the length of cable required per foot of roof length.  Note: Multiplier shown includes 1 foot of gutter cable for each foot of roof edge.  If cable is not installed in gutter, subtract 1.0 from the overhang multiplier.

Dimensions you will need:

Figure 2

Cable Installation Patterns:

One cable may cover both roof and gutter areas, or separate cables can be used.

Add this number calculated above to the length of the downspout. (A in Figure 2).  Note: If a downspout is located anywhere other than at the end of the cable routing, that downspout will require double length of cable (B in Figure 2).  Add extra cable for valleys (6' per valley, C in Figure 2) and around dormers (D in Figure 2)

Example: 28 feet of roof, 24" overhang (therefore using overhang multiplier of 5.3), 1 downspout @ 10' at end of cable run, 1 valley, 1 dormer with 30' perimeter.

Cable length = (28 x 5.3) + 10 + 6 + 30 = 194.4 feet.  Select ADKS-1000 which is 200 feet since it is the closest to 194.4 feet.  Excess cable can be used in the valley or downspout.  The de-icing cable cannot be cut or altered, doing so voids the warranty, and once cut it cannot be repaired.

Easy Heat Owners/Installation Manual

You must have the free Adobe Acrobat Reader plug-in.

Optional RS-2 Roof Cable Deicing Control

Control expense and energy use in electric roof cable protection automatically with Roof Sentry (RS-2). The RS-2 requires two conditions to be present before it energizes roof deicing cable: cold temperatures (ON, 38°F; OFF, 48°F) and the presence of runoff water from the roof in contact with its sensor wire.  If only one of the conditions exists, the control will not energize the cable.

  • 1200 Watt capacity at 120 VAC, one per cable.
  • State-of-the art electronic sensor.
  • Weather resistant enclosure.
  • Installs quickly and easily.
  • CSA Certified

Easy Heat RS-2 Roof Sentry Control Installation Instructions (1.5 mb)

You must have the free Adobe Acrobat Reader plug-in.

Optional Extra Clips and Spacers: Extra roof cable clips and cable spacers (enough are already included with each ADKS kit to complete the installation, but extra can be ordered)

Extra Roof Cable Clips Extra Roof Cable Spacers

Part# CSK-12 (Combination package of 19 Extra Roof Cable Clips & 16 Extra Roof Cable Spacers)


Secure Online Ordering
*Delivery time: typically ships in 1 working day or less plus allow additional time for your selected UPS or FedEx shipping method.  Your shipping cost will be displayed in your shopping cart.

Item ID Catalog # Description

Price

Click "Select" below to see the actual quantity in stock
EASY10001 ADKS-100 Heat Trace Cable (20 Feet, 100 Watt) includes 1 CSK-12 $35.18 Select
EASY10004 ADKS-150 Heat Trace Cable (30 Feet, 150 Watt) includes 1 CSK-12 $40.02 Select
EASY10005 ADKS-300 Heat Trace Cable (60 Feet, 300 Watt) includes 2 CSK-12's $50.26 Select
EASY10006 ADKS-400 Heat Trace Cable (80 Feet, 400 Watt) includes 3 CSK-12's $60.06 Select
EASY10007 ADKS-500 Heat Trace Cable (100 Feet, 500 Watt) includes 4 CSK-12's $64.59 Select
EASY10042 ADKS-600 Heat Trace Cable (120 Feet, 600 Watt) includes 4 CSK-12's $83.45 Select
EASY10037 ADKS-800 Heat Trace Cable (160 Feet, 800 Watt) includes 5 CSK-12's $96.77 Select
EASY10002 ADKS-1000 Heat Trace Cable (200 Feet, 1000 Watt) includes 7 CSK-12's $118.94 Select
EASY10003 ADKS-1200 Heat Trace Cable (240 Feet, 1200 Watt) includes 8 CSK-12's $130.30 Select
Optional Control:
EASY10011 RS-2 Roof Sentry De-Icer Control (Controls 1 ADKS Cable) $80.65 Select
Optional Extra Clips and Spacers:
EASY10012 CSK-12 19 Extra Roof Cable Clips & 16 Extra Roof Cable Spacers $5.21 Select

*This delivery time is for normal conditions and is subject to Easy Heat factory availability.

EasyHeat is a registered trademark of EasyHeat, Inc.


Home ] Up ]

view cart

Mor Electric Heating Assoc., Inc. is a Distributor of Industrial, Commercial and Residential Heaters and Controls.
Always consult manufacturers installation instructions for proper installation of the products or systems shown on this website.

 When you are ready to order you will be taken to our secure online ordering website: www.MorElectricHeating.com.
Visit our other websites for home, office and factory infrared heating, fans and air conditioning: www.InfraredHeaters.com and www.Fans-Plus.com.

MOR ELECTRIC HEATING ASSOC., INC.
5880 Alpine Ave. NWComstock Park, MI 49321  USATel 616-784-1121800-442-2581Fax 616-784-7775 E-mail sales@heatersplus.com