Chromalox SRF-RG
Commercial Grade Roof & Gutter Heat Trace
Cable


Mor Electric Heating is an authorized distributor for
Chromalox®
Links to other roof heating cable:
Easy Heat ADKS Roof and Gutter Heat Trace Cable
EASYHEAT PSR Pre-Terminated Self-Regulating
Freeze Protection Cable for Water Pipes and Roofs
ETI LCD-7 Automatic Control For Snow
Melting
ETI Heat Trace Controls

Chromalox SRF-RG self-regulating heating cable provides reliable freeze protection of
roofs and gutters. Because SRF-RG is self-regulating,
it automatically adjusts to the appropriate heat
output as ambient conditions change, making it both
energy efficient and cost effective. The protective
waterproof outer jacket is suitable for wet
applications in downspouts and roof drains.
Likewise, it is easy to apply SRF-RG following
the provided instruction sheets and utilizing the
required accessory kits. It can be cut-to-length and
single overlapped. Simply trace the gutter or roof and
energize the cable when precipitation is expected.
From that point on, SRF-RG will rapidly increase its
output when in contact with snow or ice, providing maximum melting power. When the roof and
gutters are clear of snow and ice, the SRF-RG cable
will regulate its output and save energy.
Features
- 12 Watts/foot in snow or ice @32°F
|
FM Approved
|
-
UL Listed for snow melting and de-icing equipment.
|
CSA Certified
|
Cut to length in field
|
Self-Regulating output
|
Specifications
 |
Buss Wire -16 AWG, Nickel-Coated Copper |
 |
Outer Jacket
- UV Stabilized
Weatherproof Jacket |
 |
Environmental Use
- Use only in Ordinary
Areas, 150°F Max.
Exposure Temperature |
 |
Output Wattage
- 12 W/Ft. in Snow or Ice
@ 32°F |
 |
Service Voltage
- SRF 5-1RG = 120 Vac,
SRF 5-2RG = 208 - 277 Vac |

Ground Braid
- Tinned Copper Braid Under
Jacket

1. To calculate the amount of cable needed, multiply roof edge length to be heat
traced by the spacing factor. The spacing factor (feet of cable required per
foot of roof edge) is determined by the roof overhang, heating width (A) and
heating height (B):
| Roof Overhang |
Heating Width |
Heating Height |
Spacing Factor |
| 12" |
2 |
18" |
2 |
| 24" |
2 |
30" |
3 |
| 36" |
2 |
42" |
4 |
2. Add the total gutter length and the total downspout length to
the figure calculated in step 1.
3. Also add enough cable to provide a drip
loop prior to going into the box, typically 6" to 36",
to get the total length of cable required.
4.
Determine how many circuits are required. Divide the total length of cable by
the maximum circuit length. Round that number up (for example, 2.1 to 3) to get
the total number of circuits.Maximum Circuit Length (Ft.)

Note: The SRF-RG cable is sold by the foot and therefore a
custom order. Once the order is placed it cannot be cancelled or
returned once you receive the cable. This is because the cable is cut
to length here, or at Chromalox, for your order, from your requested length.
WARNING — A ground fault protection device
is required by NEC to minimize the danger of fire if the heating cable is
damaged or improperly installed. A minimum trip level of 30 mA is recommended to
minimize nuisance tripping. Suggested breakers with 30 mA ground fault
trip levels are:
• 120V Single Pole Westinghouse GFEPD, Square D QO, EPD Style
• 120/240V Single Pole Westinghouse GFEPD, Square D QO, EPD Style.

Accessories:

RG-SK-1 Splice Kit Materials to splice two cables.
(Not a T-Splice)
Special weatherproof sleeving to insure
trouble-free operation

RDK-1 Downspout Hanger Kit Downspout hangers (1) to suspend cable in downspout

RCK-1 Roof Clips Roof clips (10) to attach cable
(Use roof cement to secure)


RG-PK-1 Power & End Seal & Warning Labels,
Power termination into junction box with one end seal (seals cable at end termination) and two "Warning-Electric
Traced" labels.

AT-1
Aluminum High Temperature Tape roll (Secures Heat Trace in Gutter) with a pressure-sensitive acrylic adhesive backing. 2" (5.08 cm) wide x
150 ft. (54.86 m) long roll, 200° F (93°C) rated. 2 mil. thickness
(Specifications may vary.)
 |
ETI MODEL GIT-3A
Automatic gutter ice melting control.
Control operates ice melting heaters only
while required Gutter-mounted sensor and a
control enclosure connected by a 12' 6" cable. Senses
both moisture and temperature conditions in the gutter or down spout.
Ice melting heaters operate at temperatures at or below 38º F (3.3º
C). 120, 208/240 or 277 volt supply |
|
Secure
Online Credit Card Ordering - SSL Encryption
delivery time: typically ships in 1 working day or less plus the time of
your selected UPS shipping method. Price below does not include shipping cost which is calculated using your address before entering your credit card number. |
|
Item Id |
Catalog No. |
Description |
Price |
Click "Select" below to see
the actual quantity in stock |
|
CHROM386329 |
SRF5-1RG |
120V Cable with
braid and weatherproof jacket (Price per foot) |
$5.95 |
 |
|
CHROM386337 |
SRF5-2RG |
208 - 277V Cable
with braid and weatherproof jacket (Price per foot) |
$6.15 |
 |
|
CHROM386206 |
RG-PK-1 |
Power & End Seal & Warning Labels |
$28.50 |
 |
|
CHROM386214 |
RG-SK-1 |
Splice Kit |
$23.65 |
 |
|
CHROM340179 |
RCK-1 |
Roof Clips |
$8.50 |
 |
|
CHROM340160 |
RDK-1 |
Downspout Hanger |
$8.50 |
 |
|
CHROM383355 |
AT-1 |
Aluminum tape roll |
$47.90 |
 |
Chromalox® is a registered trademark.
|